Showing 35–51 of 375 results

1460-1914 Capillary column hanger

Capillary column hanger for Agilent GCs. Compatible with Agilent 58/68/78XX Series GCs.

18713-60040 GC electron capture detector standard in isooctane, 0.5 mL

Specifications: Analyte Count 2 CAS Number 309-00-2 58-89-9 Concentration Aldrin 0.033 µg/mL CAS #: 309-00-2 gamma-BHC (lindane) 0.033 µg/mL CAS

18789-60060 NPD standard in isooctane, 3 x 0.5 mL ampoules

NPD standard in isooctane, 3 x 0.5 mL ampoules. (China only. Hazardous product, will be shipped from another warehouse. The corresponding invoice will be provided by Agilent China Shanghai Legal entity).

190047900 Digestion tubes, 50 mL

Digestion tubes, 50 mL, with threaded, natural linerless cap, 500/pk. All polypropylene suitable for digestion with 36 and 54-well block digestors. Certified for low leachable metal content. Tube has 5 mL graduations to 50 mL, certified for volume accuracy to 0.5 %. Dimensions: 30 mm od x 110 mm H with tapered body, wide neck, and flat base for added stability. Supplied with CoA confirming low leachable metals content and volume accuracy.

19091-60620E Deactivated Fused Silica, 5 m, 0.10 mm, 0.36 mm OD, 5 inch cage

Specifications:
Capillary Tubing
  • Fused Silica
Format
  • 5 inch
Inner Diameter (ID)
  • 0.1 mm
Length
  • 5 m
Outer Diameter (OD)
  • 0.36 mm
UNSPSC Code
  • 41115710

19091J-413 J&W HP-5 GC Column, 30 m, 0.32 mm, 0.25 µm, 7 inch cage

J&W HP-5 GC Column, 30 m, 0.32 mm, 0.25 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

19091S-433 J&W HP-5ms GC Column, 30 m, 0.25 mm, 0.25 µm, 7 inch cage

J&W HP-5ms GC Column, 30 m, 0.25 mm, 0.25 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.

2140-0820 InfinityLab long-life deuterium DAD/MWD lamp

nfinityLab long-life deuterium DAD/MWD lamp, with RFID tag. For Agilent diode array detectors with standard flow cell (G1315C/D, DAD of

23750-911 InfinityLab Poroshell 120 EC-C18, 3.0 mm, 2.7 µm, UHPLC guard, 3/pk

InfinityLab Poroshell 120 EC-C18, 3.0 mm, 2.7 µm, UHPLC guard, 3/pk. Guard columns recommended for all column applications, especially for samples with particulate matter, ensuring column longevity and efficiency.

2410020500 Nebulizer capillary tubing

Tubing, capillary, nebulizer, for ketone-based organic samples, per m

2950-0232 HEX Nut

Nut-Hex-Dbl-Cham 5/16-20-Thd .094-In-Thk
Specifications
Technique
  • GC
UNSPSC Code
  • 41115700

3710026400 Silicon tubing

Silicon tubing, 1 mm id, 3 mm od. Used for connecting nebulizer capillary to SPS probe line