Showing 137–153 of 424 results

0100-0969 Tee, 1/16 in, 316 SST, low dead volume

Specifications:
Body Material
  • Stainless Steel
Connection Size 1
  • 1/16 in
Ferrule Type
  • Stainless Steel
UNSPSC Code
  • 41115717

G1530-61200 Non-APG, ‘Y’ remote start cable

Non-APG, 'Y' remote start cable, used with series 5890 and 7890 gas chromatography systems.

8121-0940 80-1000 V telecom cable

80-1000 V telecom cable, with connector, used with series 5973 and 5975, systems 5973A and 5975T.
Specifications:
UNSPSC Code
  • 41115700

G1375-87314 Capillary, PEEK/fused silica

Capillary, PEEK/fused silica, 50 µm id, 400 mm length, 2x fittings, 1 union. OQ/PV capillary for u-LC system.

18789-60060 NPD standard in isooctane, 3 x 0.5 mL ampoules

NPD standard in isooctane, 3 x 0.5 mL ampoules. (China only. Hazardous product, will be shipped from another warehouse. The corresponding invoice will be provided by Agilent China Shanghai Legal entity).

18713-60040 GC electron capture detector standard in isooctane, 0.5 mL

Specifications: Analyte Count 2 CAS Number 309-00-2 58-89-9 Concentration Aldrin 0.033 µg/mL CAS #: 309-00-2 gamma-BHC (lindane) 0.033 µg/mL CAS

G3452-60552 S/SL inlet manifold assembly, 100 psi

S/SL inlet manifold assembly, 100 psi, used with series 7890 gas chromatography systems. This replacement part can only be ordered in connection with a repair by an Agilent certified Engineer. Please contact your Agilent Service Contact Center.

G1946-20213 Ferrule

Ferrule, for nebulizer needle, graphite-filled polyimide, 0.3 mm.
Specifications:
Material
  • Graphite-filled polyimide
Technique
  • LC/MS
UNSPSC Code
  • 41115717

G1530-61100 1/8 in OD X 250 cm Cu Tubing Coil Assembly

Specifications: Instrument Compatibility 7890B 8860A 8890A Intuvo 9000 Technique GC

G1969-85000 ESI-L LCMS Tuning Solution

ESI-L LCMS Tuning Solution. Tuning Mix for LCMS Instruments (Including ESI-TOF).

5067-4710 Sample loop kit

Sample loop kit, stainless steel, 100 μL. For G1367E, G4226A high performance autosampler.

5185-5820 Cap, screw, blue, PTFE/red silicone septa, 500/pk

Cap, screw, blue, PTFE/red silicone septa, 500/pk. These 9 mm blue screw caps come in 500/pks and include a septum made from white PTFE/red silicone septum bi-layer. This combination is suited for a broad range of applications, however, is one of the main choices for HPLC applications where the sample is less volatile and/or were snap or crimp style vials are not appropriate. This particular version is the most-widely used design for 2 mL vials. It is compatible wth all wide-opening 2 mL glass and polyproplene vials, 2 mL micro vials and 2 mL High Recovery Vials. While it is the most common option for 2 mL vials a close second are snap top style vials, however, they are less common. These screw caps being press-fit (non-bonded) are the most sustainable cap option as the various components can be separated for easier disposal and recycling.