2301P and 2501P: Features and Benefits
| • 2301P: Measures 0.3 µm to 25 µm |
| • 2501P: Measures 0.5 µm to 25 µm |
| • 0.1 CFM (2.83 LPM) flow rate |
| • Long life laser diode technology |
| • Measures up to 4 channels of simultaneous data |
| • Accurate in high particle concentration environments |
| • Internal vacuum pump |
| • Internal HEPA filter |
| • Connect using Modbus RTU/ASCII over isolated RS-485 |
| • Complies with ISO 21501-4 and JIS B9921 standards |
| • Easy to clean and wipe down with minimal particle traps |
| • Versatile mounting options |
| • Alarm light |
| • LED Indicators |
| • Seamless integration into a facility monitoring system |
| • Lightweight stainless steel enclosure |
| • 2 year warranty. Extended warranties available. |
Specifications
| Model | 2301P | 2501P |
| Size Range | 0.3 µm to 25 µm | 0.5 µm to 25 µm |
| Size Channels | Factory calibrated at 0.3, 0.5, 1.0, 5.0 µm | Factory calibrated at 0.5, 1.0, 2.5, 5.0 µm |
| Number of Channels | 4 channels | 64 channels |
| Counting Efficiency | 50% @ 0.3µm; 100% for particles > 0.45 µm per JIS | 50% @ 0.5µm; 100% for particles > 0.75 µm per JIS |
| Flow Rate | 0.1 CFM (2.83 LPM) | |
| Concentration Limits | 10,000,000 particles/ft3 @ 10% coincidence (per ISO 21501-4), 20,000,000 particles/ft3 @ 10% coincidence (as tested and validated1) |
|
| Light Source | Long life laser diode | |
| Zero Count | < 1 count / 60 minutes (< 1 particles /6 ft3) | |
| Calibration | NIST traceable | |
| Vacuum Source | Internal vacuum pump with HEPA filter | |
| Filtered Exhaust | Internal HEPA filter | |
| Airflow | Internally monitored | |
| Alarm | Alarm LED ring | |
| Communication Modes | MODBUS™ RTU or ASCII outputs (over isolated RS-485) | |
| Standards | ISO 21501-4 and JIS B9921 | |
| Instrument Calibration | Recommended minimum once per year | |
| External Surface | Stainless steel | |
| Dimensions (L x W x H) | 3.59” x 1.83” x 5.66” (9.1 cm x 4.6 cm x 14.3 cm) including probes and connectors | |
| Weight | 1.94 lb. (0.88 kg) | |
| Accessories | Wiring Connector, operating manual on USB flash drive | |
| Optional Accessories | Power Supply, Remote Mounting Bracket, Stainless Steel Barbed Isoprobe (0.1 CFM/2.83 LPM), Purge Filter Assembly, and Sample & Vacuum Tubing |
|
| Sample Time | 1 second to 18 hours | |
| Power | 9 – 24 VDC (< 2.5 watts) | |
| Operating Conditions | 41° to 104°F (5° to 40°C) / 20% to 95% non-condensing | |
| Storage Conditions | 32° to 122°F (0° to 50°C) / Up to 98% non-condensing | |
| Warranty | 2 year limited warranty. Extended warranties available. |


















Reviews
There are no reviews yet.