1260 Infinity III Hybrid Multisampler (G7167C)
The 1260 Infinity III Hybrid Multisampler is an HPLC autosampler that offers both classical flow-through injection and Agilent Feed Injection modes. In classical flow-through mode, the mobile phase delivered by the HPLC pump flows through the loaded sample loop. In Feed Injection mode, sample is infused continuously into the mobile phase stream.
For samples with strong solvent, for example after QuEChERS sample preparation in food analysis, sample solvent effect is a challenge that leads to peak break through and poor peak shapes, especially as injection volumes increase. Agilent Feed Injection can mediate the strong sample solvent effect by mixing sample and mobile phase directly at injection to improve peak shapes and sensitivity. By applying Feed Injection mode, there is no need for extra sample preparation, and the perfect peak shapes enable easy peak integration.
1260 Infinity III Multisampler (G7167A)
The 1260 Infinity III Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Agilent LC stack.
The 1260 Infinity III Multisampler is optimized for highest flexibility. The unique dual-needle design enables cycle times to be reduced by overlapping sample runs and injection cycles. The multiwash capability reduces carryover to less than 9 ppm.
1260 Infinity III Online Sample Manager (G3167A)
The 1260 Infinity III Online Sample Manager is an online sampling module that connects the analytical world with the process world. The module provides automated sample analysis via direct injections or retained samples from flow reactors, batch reactors, as well as upstream bioreactors and downstream purification devices.
The Online Sample Manager supports both classical flow-through injection and Agilent Feed Injection, mediating the chromatographic sample diluent incompatibility of challenging process samples. The Online Sample Manager provides automated dilutions of up to 1:1000, retain-sample functionality, and direct analysis of the process samples, as well as automated sample preparation.
1260 Infinity III Vialsampler (G7129C)
The 1260 Infinity III Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar.
Options and upgrades are available for sample cooling and heating from 4 to 40 °C. An integrated column compartment is also available as an option or upgrade and provides thermal control to 80 °C for two columns.
1260 Infinity III Bio-Inert Multisampler (G5668A)
The 1260 Infinity III Bio-Inert Multisampler injects samples from microplate and vial at pressures up to 600 bar. It is a compact module offering a capacity of up to 6,144 samples. With its multiwash capability, you can reduce carryover to less than 9 ppm.
The metal-free sample flow path makes it the ideal injector for all biorelated applications, including analysis of mAbs, proteins in general, and oligonucleotides. For temperature-sensitive samples, a highly efficient compressor-based thermostatting system can be added. The ceramic needle, PEEK needle seat, and stainless steel-clad PEEK capillaries ensure highest injection accuracy and precision.
1260 Infinity III SFC Multisampler (G4767A)
The 1260 Infinity III SFC Multisampler is a high-capacity autosampler for supercritical fluid chromatography, bringing LC-like injection precision and reproducibility to SFC. The wide injection range supports flexible injection volumes from 0.1 to 90 µL without changing sample loops.
The 1260 Infinity III SFC Multisampler is compatible with 2 mL vials and well plates for fast, high-throughput (up to 6,144 samples) SFC and SFC/MS applications. Innovative Feed Injection technology pressurizes the sample prior to injection into the carbon dioxide (CO2) stream for utmost injection precision and reproducibility.
1290 Infinity II Preparative Open-Bed Sampler/Collector (G7158B)
The 1290 Infinity II Preparative Open-Bed Sampler/Collector is the solution for automated, high-capacity management of sample injection and fraction collection in semipreparative and preparative-scale LC purification workflows. The X-Z-theta axis probe uses novel robotic technology to minimize sample carryover during movements between fraction containers. Sample volumes can be injected from microtiter plates, vials, or vessels.
The sampler/collector provides for injection of large volumes and sample loops are available with volumes of 2, 5, 10, 20 and 90 mL. The sampler/collector is equipped with an analytical-to-preparative injector and enables easy handling of a wide variety of collection vessels with a total capacity up to 5.9 liters using 150 x 25 mm (l x od) tubes. Optimized for flow rates up to 200 mL/min, the sampler/collector can be integrated seamlessly with any Agilent solvent delivery module, additional fraction collector, recovery collector, or detector.
1290 Infinity III Variable Wavelength Detector (G7114B)
The 1290 Infinity III Variable Wavelength Detector enables highest productivity with fast analysis at up to 240 Hz data rates. Even more sample information can be acquired in dual-wavelength mode. Time-programmable wavelength switching provides optimum sensitivity and selectivity for your applications.
Lowest baseline noise and drift results in lowest detection limits for robust quantification of trace level components.'
1260 Infinity III Variable Wavelength Detector (G7114A)
The 1260 Infinity III Variable Wavelength Detector enables highest productivity with fast analysis at up to 120 Hz data rates. Even more sample information can be acquired in dual-wavelength mode. Time-programmable wavelength switching provides optimum sensitivity and selectivity for your applications.
Lowest baseline noise and drift results in lowest detection limits for robust quantification of trace level components.
1260 Infinity III Diode Array Detector WR (G7115A)
The 1260 Infinity III Diode Array Detector WR offers multiple wavelength and full spectral detection up to a 120 Hz sampling rate. Maximum flexibility is guaranteed with a wide wavelength range of 190 to 950 nm with dual-lamp design, as well as the choice of 15 analytical, preparative, and SFC flow cells. Even at high data rates, the 1260 Infinity III DAD WR enables precise identification, quantification, and peak purity analysis at trace levels.
1290 Infinity III Diode Array Detector (G7117B)
The 1290 Infinity III Diode Array Detector FS (fixed slit) delivers multiple wavelength detection with full spectra at sampling rates up to 120 Hz for fast LC separations. The Max-Light cartridge cell features optofluidic waveguides, which improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersions effects. With typical noise levels of ±0.6 µAU/cm, the 60 mm path length flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells.
Any compromising refractive index and thermal effects are almost entirely eliminated, resulting in significantly less baseline drift for more reliable and precise peak integration.
1290 Infinity III Diode Array Detector FS (G7117A)
The 1290 Infinity III Diode Array Detector FS (fixed slit) delivers multiple wavelength detection with full spectra at sampling rates up to 120 Hz for fast LC separations. The Max-Light cartridge cell features optofluidic waveguides, which improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersions effects. With typical noise levels of ±0.6 µAU/cm, the 60 mm path length flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells.
Any compromising refractive index and thermal effects are almost entirely eliminated, resulting in significantly less baseline drift for more reliable and precise peak integration.
1260 Infinity III Diode Array Detector HS (G7117C)
The 1260 Infinity III Diode Array Detector HS, with a fixed slit design, is based on the Agilent Max-Light Cartridge Cell with optofluidic waveguides, which improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersion effects. With typical detector noise levels of less than ±0.6 µAU/cm, the 60 mm flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells.
Any compromising refractive index and thermal effects are eliminated, resulting in significantly less baseline drift for more reliable and precise peak integration. Multiple wavelength and full spectral detection with up to 120 Hz data rates enable precise identification, quantification, and purity analysis at trace levels for fast LC separations.
1260 Infinity III Multiple Wavelength Detector (G7165A)
The diode array design of the 1260 Infinity III Multiple Wavelength Detector offers very low detector noise (less than ±7 μAU) for precise quantification of trace levels, regardless of the number of signals recorded. Over a wavelength range from 190 to 950 nm, simultaneous detection of up to eight compound-specific wavelengths for optimum selectivity is provided. High-speed UV detection with up to 120 Hz data rates keeps pace with the analysis speed of fast LC.
1290 Infinity III Evaporative Light Scattering Detector (G7102A)
The 1290 Infinity III Evaporative Light Scattering Detector (ELSD) is ideal for reproducible, sensitve detection of both volatile and nonvolatile compounds that cannot be detected by UV. A unique peltier cooled evaporator coupled with an original gas flow design allow subambient operation down to 10 °C. This delivers maximum sensitivity for compounds with significant volatility below 30 °C.
Novel PMT technology enables an extended dynamic range of four orders of magnitude for trace impurity analysis. This unique design provides excellent sensitivity, reproducibility, and flexibility for a multitude of applications.