1260 Infinity III Vialsampler (G7129C)

The 1260 Infinity III Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. Options and upgrades are available for sample cooling and heating from 4 to 40 °C. An integrated column compartment is also available as an option or upgrade and provides thermal control to 80 °C for two columns.

1260 Infinity III Online Sample Manager (G3167A)

The 1260 Infinity III Online Sample Manager is an online sampling module that connects the analytical world with the process world. The module provides automated sample analysis via direct injections or retained samples from flow reactors, batch reactors, as well as upstream bioreactors and downstream purification devices. The Online Sample Manager supports both classical flow-through injection and Agilent Feed Injection, mediating the chromatographic sample diluent incompatibility of challenging process samples. The Online Sample Manager provides automated dilutions of up to 1:1000, retain-sample functionality, and direct analysis of the process samples, as well as automated sample preparation.

1260 Infinity III Multisampler (G7167A)

The 1260 Infinity III Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Agilent LC stack. The 1260 Infinity III Multisampler is optimized for highest flexibility. The unique dual-needle design enables cycle times to be reduced by overlapping sample runs and injection cycles. The multiwash capability reduces carryover to less than 9 ppm.

1260 Infinity III Hybrid Multisampler (G7167C)

The 1260 Infinity III Hybrid Multisampler is an HPLC autosampler that offers both classical flow-through injection and Agilent Feed Injection modes. In classical flow-through mode, the mobile phase delivered by the HPLC pump flows through the loaded sample loop. In Feed Injection mode, sample is infused continuously into the mobile phase stream. For samples with strong solvent, for example after QuEChERS sample preparation in food analysis, sample solvent effect is a challenge that leads to peak break through and poor peak shapes, especially as injection volumes increase. Agilent Feed Injection can mediate the strong sample solvent effect by mixing sample and mobile phase directly at injection to improve peak shapes and sensitivity. By applying Feed Injection mode, there is no need for extra sample preparation, and the perfect peak shapes enable easy peak integration.

1260 Infinity III SFC Binary Pump (G4782A)

The 1260 Infinity III SFC Binary Pump is a supercritical fluid chromatography (SFC) pump that supports high-pressure gradient formation and precise mobile phase delivery up to 5 mL/min and 600 bar. It can be used with a broad range of chiral and achiral columns, and ideal for fast, high-throughput SFC and SFC/MS applications. The 1260 Infinity III SFC Binary Pump is equipped with special pistons and seals for utmost robustness under SFC conditions. Carbon dioxide (CO2) is delivered through channel A while organic modifier can be added through channel B for either isocratic or gradient elution. Channel B is fitted with a purge valve to facilitate rapid change of organic modifier.

1260 Infinity II Preparative Binary Pump (G7161A)

The 1260 Infinity II Preparative Binary Pump is an affordable high-pressure gradient pump for LC purification. The pump offers a dynamic flow rate range from 1 to 50 mL/min at up to 420 bar, allowing workflows on columns from 9.4 to 30 mm inner diameter. This versatile pump is engineered for continuous use and provides reliable and rugged performance through a dual-piston, rapid-refill design. It offers automated seal wash for increased seal lifetime plus outstanding retention time stability, and is ideally suited for daily operation within a broad range of semipreparative applications.

1260 Infinity III Bio-Inert Pump (G5654A)

The 1260 Infinity III Bio-Inert Pump is a quaternary UHPLC pump that is made of bio-inert material for use in biological and extreme pH applications. This pump enables gradient formation and solvent blending from up to four solvents and operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Bio-Inert Pump is resistant to corrosion by high salt concentrations (2 M) and can handle a wide pH range from 1–13, and even up to pH 14 for short-term use. This pump is ideal for protein and NBE characterization.

1290 Infinity III Bio High Speed Pump (G7132A)

The 1290 Infinity III Bio High-Speed Pump is a binary UHPLC pump consisting of biocompatible material for use in biopharma and other applications utilizing high salt and extreme pH conditions. It uses high-pressure blending from up to two solvents at pressures up to 1300 bar and flow rates up to 5 mL/min. This Bio High-Speed Pump has an exceptionally low delay volume, achieving high throughput and highest resolution for the most demanding applications, giving you highest confidence in your results. It is the ideal front end for LC/MS applications.

1290 Infinity III High-Speed Pump (G7120A)

The 1290 Infinity III High Speed Pump uses high-pressure mixing for UHPLC gradient formation and solvent blending from up to two solvents at pressures up to 1300 bar and flow rates up to 5 mL/min. The 1290 Infinity III High Speed Pump has an exceptionally low delay volume, which allows you to run ultrafast gradients for narrow-bore UHPLC applications. This capability makes this pump the ideal front-end for LC/MS applications. The full ISET range allows you to seamlessly transfer existing methods from different instruments, including current Agilent systems as well as instruments from other manufacturers.

1260 Infinity III Binary Pump (G7112B)

The 1260 Infinity III Binary Pump uses high-pressure mixing for UHPLC gradient formation and solvent blending from one or two solvents at pressures up to 600 bar and flow rates up to 5 mL/min. The 1260 Infinity III Binary Pump is ideally suited for a broad range of UHPLC applications using columns with conventional, superficially porous or sub-2-micron particles. This pump delivers reproducible gradients for routine HPLC or UHPLC applications with UV or MS detection where speed, resolution, and uncompromised data quality are essential.

1260 Infinity III Quaternary Pump VL (G7111A)

The 1260 Infinity III Quaternary Pump is a gradient pump that uses low-pressure mixing for UHPLC gradient formation and solvent blending from up to four solvents. This pump operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Quaternary Pump combines proven reliability with highest flexibility in automated gradient formation and solvent blending, and is recommended for a wide range of research and routine applications as well as for method development.

1260 Infinity III Quaternary Pump (G7111B)

The 1260 Infinity III Quaternary Pump is a gradient pump that uses low-pressure mixing for UHPLC gradient formation and solvent blending from up to four solvents. This pump operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Quaternary Pump combines proven reliability with highest flexibility in automated gradient formation and solvent blending, and is recommended for a wide range of research and routine applications as well as for method development.

1260 Infinity III Isocratic Pump (G7110B)

The 1260 Infinity III Isocratic Pump provides isocratic solvent management for HPLC, UHPLC, and GPC/SEC applications. This pump operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Isocratic Pump is the ideal workhorse for demanding QA/QC tasks and routine applications that require maximum uptime at low operating and maintenance cost. This pump is ideal for GPC/SEC applications where run-to-run and day-to-day precision of retention times is crucial.

1260 Infinity III Bio Flexible Pump (G7131C)

The 1260 Infinity III Bio Flexible Pump is a UHPLC pump comprising biocompatible components, developed for biopharma applications and for other analyses requiring high-salt and extreme-pH conditions. This pump enables quaternary solvent delivery at pressures up to 800 bar and flow rates up to 5 mL/min. The 1260 Infinity III Bio Flexible Pump combines high performance and simplified operation with remarkable flexibility in automated gradient formation and solvent blending. This pump also facilitates seamless method transfer using Intelligent System Emulation Technology (ISET) and automated buffer blending.
 

1260 Infinity III Flexible Pump (G7104C)

The 1260 Infinity III Flexible Pump is a quaternary UHPLC pump that provides gradient formation and solvent blending from up to four solvents. This UHPLC pump enables quaternary solvent delivery at pressures up to 800 bar and flow rates up to 5 mL/min. The 1260 Infinity III Flexible Pump combines high performance and simplified operation with highest flexibility in automated gradient formation and solvent blending. This UHPLC pump also facilitates seamless method transfer using ISET and automated buffer blending.

1260 Infinity III Fluorescence Detector (G7121A)

The 1260 Infinity III Fluorescence Detector offers time-programmable excitation and emission wavelength switching. The proven optical and electronic design provides the highest sensitivity for the analysis of trace-level components. This detector can be used with any Agilent InfinityLab LC Series system or other LC instrument. Benefit from highest sensitivity for the analysis of trace-level components featuring high-speed detection with up to 74 Hz data rates for narrow LC peaks.