Showing 52–68 of 102 results

1290 Infinity III Variable Wavelength Detector (G7114B)

The 1290 Infinity III Variable Wavelength Detector enables highest productivity with fast analysis at up to 240 Hz data rates. Even more sample information can be acquired in dual-wavelength mode. Time-programmable wavelength switching provides optimum sensitivity and selectivity for your applications. Lowest baseline noise and drift results in lowest detection limits for robust quantification of trace level components.'

1290 Infinity II Preparative Open-Bed Sampler/Collector (G7158B)

The 1290 Infinity II Preparative Open-Bed Sampler/Collector is the solution for automated, high-capacity management of sample injection and fraction collection in semipreparative and preparative-scale LC purification workflows. The X-Z-theta axis probe uses novel robotic technology to minimize sample carryover during movements between fraction containers. Sample volumes can be injected from microtiter plates, vials, or vessels. The sampler/collector provides for injection of large volumes and sample loops are available with volumes of 2, 5, 10, 20 and 90 mL. The sampler/collector is equipped with an analytical-to-preparative injector and enables easy handling of a wide variety of collection vessels with a total capacity up to 5.9 liters using 150 x 25 mm (l x od) tubes. Optimized for flow rates up to 200 mL/min, the sampler/collector can be integrated seamlessly with any Agilent solvent delivery module, additional fraction collector, recovery collector, or detector.

1260 Infinity III SFC Multisampler (G4767A)

The 1260 Infinity III SFC Multisampler is a high-capacity autosampler for supercritical fluid chromatography, bringing LC-like injection precision and reproducibility to SFC. The wide injection range supports flexible injection volumes from 0.1 to 90 µL without changing sample loops. The 1260 Infinity III SFC Multisampler is compatible with 2 mL vials and well plates for fast, high-throughput (up to 6,144 samples) SFC and SFC/MS applications. Innovative Feed Injection technology pressurizes the sample prior to injection into the carbon dioxide (CO2) stream for utmost injection precision and reproducibility.

1260 Infinity II Prep Autosampler (G7157A)

GLP features. Early maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits and feedback messages. Electronic records of maintenance and errors.

1260 Infinity III Bio-Inert Multisampler (G5668A)

The 1260 Infinity III Bio-Inert Multisampler injects samples from microplate and vial at pressures up to 600 bar. It is a compact module offering a capacity of up to 6,144 samples. With its multiwash capability, you can reduce carryover to less than 9 ppm. The metal-free sample flow path makes it the ideal injector for all biorelated applications, including analysis of mAbs, proteins in general, and oligonucleotides. For temperature-sensitive samples, a highly efficient compressor-based thermostatting system can be added. The ceramic needle, PEEK needle seat, and stainless steel-clad PEEK capillaries ensure highest injection accuracy and precision.

1260 Infinity III Vialsampler (G7129C)

The 1260 Infinity III Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. Options and upgrades are available for sample cooling and heating from 4 to 40 °C. An integrated column compartment is also available as an option or upgrade and provides thermal control to 80 °C for two columns.

1260 Infinity III Online Sample Manager (G3167A)

The 1260 Infinity III Online Sample Manager is an online sampling module that connects the analytical world with the process world. The module provides automated sample analysis via direct injections or retained samples from flow reactors, batch reactors, as well as upstream bioreactors and downstream purification devices. The Online Sample Manager supports both classical flow-through injection and Agilent Feed Injection, mediating the chromatographic sample diluent incompatibility of challenging process samples. The Online Sample Manager provides automated dilutions of up to 1:1000, retain-sample functionality, and direct analysis of the process samples, as well as automated sample preparation.

1260 Infinity III Multisampler (G7167A)

The 1260 Infinity III Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Agilent LC stack. The 1260 Infinity III Multisampler is optimized for highest flexibility. The unique dual-needle design enables cycle times to be reduced by overlapping sample runs and injection cycles. The multiwash capability reduces carryover to less than 9 ppm.

1260 Infinity III Hybrid Multisampler (G7167C)

The 1260 Infinity III Hybrid Multisampler is an HPLC autosampler that offers both classical flow-through injection and Agilent Feed Injection modes. In classical flow-through mode, the mobile phase delivered by the HPLC pump flows through the loaded sample loop. In Feed Injection mode, sample is infused continuously into the mobile phase stream. For samples with strong solvent, for example after QuEChERS sample preparation in food analysis, sample solvent effect is a challenge that leads to peak break through and poor peak shapes, especially as injection volumes increase. Agilent Feed Injection can mediate the strong sample solvent effect by mixing sample and mobile phase directly at injection to improve peak shapes and sensitivity. By applying Feed Injection mode, there is no need for extra sample preparation, and the perfect peak shapes enable easy peak integration.

1260 Infinity III SFC Binary Pump (G4782A)

The 1260 Infinity III SFC Binary Pump is a supercritical fluid chromatography (SFC) pump that supports high-pressure gradient formation and precise mobile phase delivery up to 5 mL/min and 600 bar. It can be used with a broad range of chiral and achiral columns, and ideal for fast, high-throughput SFC and SFC/MS applications. The 1260 Infinity III SFC Binary Pump is equipped with special pistons and seals for utmost robustness under SFC conditions. Carbon dioxide (CO2) is delivered through channel A while organic modifier can be added through channel B for either isocratic or gradient elution. Channel B is fitted with a purge valve to facilitate rapid change of organic modifier.

1260 Infinity II Preparative Binary Pump (G7161A)

The 1260 Infinity II Preparative Binary Pump is an affordable high-pressure gradient pump for LC purification. The pump offers a dynamic flow rate range from 1 to 50 mL/min at up to 420 bar, allowing workflows on columns from 9.4 to 30 mm inner diameter. This versatile pump is engineered for continuous use and provides reliable and rugged performance through a dual-piston, rapid-refill design. It offers automated seal wash for increased seal lifetime plus outstanding retention time stability, and is ideally suited for daily operation within a broad range of semipreparative applications.

1260 Infinity III Bio-Inert Pump (G5654A)

The 1260 Infinity III Bio-Inert Pump is a quaternary UHPLC pump that is made of bio-inert material for use in biological and extreme pH applications. This pump enables gradient formation and solvent blending from up to four solvents and operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Bio-Inert Pump is resistant to corrosion by high salt concentrations (2 M) and can handle a wide pH range from 1–13, and even up to pH 14 for short-term use. This pump is ideal for protein and NBE characterization.

1290 Infinity III Bio High Speed Pump (G7132A)

The 1290 Infinity III Bio High-Speed Pump is a binary UHPLC pump consisting of biocompatible material for use in biopharma and other applications utilizing high salt and extreme pH conditions. It uses high-pressure blending from up to two solvents at pressures up to 1300 bar and flow rates up to 5 mL/min. This Bio High-Speed Pump has an exceptionally low delay volume, achieving high throughput and highest resolution for the most demanding applications, giving you highest confidence in your results. It is the ideal front end for LC/MS applications.

1290 Infinity III High-Speed Pump (G7120A)

The 1290 Infinity III High Speed Pump uses high-pressure mixing for UHPLC gradient formation and solvent blending from up to two solvents at pressures up to 1300 bar and flow rates up to 5 mL/min. The 1290 Infinity III High Speed Pump has an exceptionally low delay volume, which allows you to run ultrafast gradients for narrow-bore UHPLC applications. This capability makes this pump the ideal front-end for LC/MS applications. The full ISET range allows you to seamlessly transfer existing methods from different instruments, including current Agilent systems as well as instruments from other manufacturers.

1260 Infinity III Binary Pump (G7112B)

The 1260 Infinity III Binary Pump uses high-pressure mixing for UHPLC gradient formation and solvent blending from one or two solvents at pressures up to 600 bar and flow rates up to 5 mL/min. The 1260 Infinity III Binary Pump is ideally suited for a broad range of UHPLC applications using columns with conventional, superficially porous or sub-2-micron particles. This pump delivers reproducible gradients for routine HPLC or UHPLC applications with UV or MS detection where speed, resolution, and uncompromised data quality are essential.

1260 Infinity III Quaternary Pump VL (G7111A)

The 1260 Infinity III Quaternary Pump is a gradient pump that uses low-pressure mixing for UHPLC gradient formation and solvent blending from up to four solvents. This pump operates at pressures up to 600 bar and flow rates up to 10 mL/min. The 1260 Infinity III Quaternary Pump combines proven reliability with highest flexibility in automated gradient formation and solvent blending, and is recommended for a wide range of research and routine applications as well as for method development.