ProfIC Vario 15 AnCat
The Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique, sequential suppression, and conductivity detection enables fully automated determination of anions and cations. "Partial Loop Injection" enables the injection of various sample volumes.
Typical areas of application:
- Universal use for all types of samples
- From trace analysis to waste water analysis
- Great differences in concentration in a single sample series
Tag Flash Point Certified Reference Material (ASTM D56)
The Tag Flash Point Certified Reference Material (CRM) has been developed for laboratories carrying out Tag Closed Cup Flash Point testing in accordance with ASTM D56.
Manufactured by Stanhope-Seta under UKAS ISO 17034 accreditation, the CRM provides a traceable solution for routine verification of compatible Tag Flash Point instruments, helping laboratories maintain confidence in instrument performance between calibration intervals.
With a nominal flash point value of 40 °C, the CRM supports routine quality control, instrument verification and ISO 17025 quality systems.
This product is suitable if your laboratory:
- Performs ASTM D56 testing
- Uses a Tag Closed Cup Flash Point tester
- Carries out routine instrument verification
- Requires traceable Certified Reference Materials
- Operates under ISO 17025 or similar quality systems
- Manufactured under UKAS ISO 17034 accreditation
- Nominal flash point value of 40 °C
- 100 mL bottle
- Two-year shelf life
- Supplied with ISO 17034 Certificate
- Safety Data Sheet included
- ASTM D56
Water Separation Index (WSI) Jet Fuel Certified Reference Material (ASTM D8073; IP 624)
The Water Separation Index (WSI) Jet Fuel Certified Reference Material (CRM) has been developed for laboratories carrying out Water Separation Index testing in accordance with ASTM D8073 and IP 624.
Manufactured by Stanhope-Seta under UKAS ISO 17034 accreditation, the CRM provides a traceable solution for routine verification of compatible Water Separation Instruments (WSI), helping laboratories maintain confidence in analyser performance between calibration intervals.
With a nominal Water Separation Index (WSI) value of 95, the CRM supports routine quality control, instrument verification and ISO 17025 quality systems.
This product is suitable if your laboratory:
- Performs ASTM D8073 or IP 624 testing
- Uses a Water Separation Instrument (WSI)
- Carries out routine instrument verification
- Requires traceable Certified Reference Materials
- Operates under ISO 17025 or similar quality systems
- Manufactured under UKAS ISO 17034 accreditation
- Nominal Water Separation Index (WSI) value of 95
- 250 mL bottle
- Two-year shelf life
- Supplied with ISO 17034 Certificate
- Safety Data Sheet included
- ASTM D8073
- IP 624
Zeeman Effect
Product Summary
In this experiment, the student observes the interference pattern from a Fabry-Perot interferometer that results from the 546.1 nm spectral line of a mercury lamp immersed in a uniform magnetic field. The magnetic field is varied from zero to nearly 1 Tesla.
Initially, the light is viewed along an axis perpendicular to the magnetic field axis. A polarizer is used to show the three lines due to light that is polarized parallel to the field axis and to show the six lines that are polarized perpendicular to the field axis. The pattern may also be viewed along the field axis where the light is circularly polarized.
Finally, the pattern that is polarized perpendicular to the field axis is used to calculate the Bohr magneton. All atomic magnetic moments are integral or half-integral multiples of the Bohr magneton.